Overview

Airmax 230V Control Panel

The ETL listed NEMA 3R Control Panel comes standard with all PondSeries and LakeSeries Fountains. This lockable, weather resistant control panel includes two separate 24-hour digital timers for both fountains and lights, contactor, and GFCI protection. Constructed of Thermoset Fiberglass for superior durability. Available in 230V 60hz, single phase.
The enclosure measures 16"W x 17.75"H x 8.5"D and works with Airmax 1/2 HP - 2 HP PondSeries Fountains as well as 2 HP, 3 HP, and 5 HP LakeSeries Fountains. Airmax Control Panels are covered under the system warranty.
Programmable 24-Hour Digital Timers: Allows you to independently program your fountain and lights run times.
Ground-Fault Circuit Interrupter: Fast-acting circuit breaker which will shut off electrical power in the event of a ground fault.
Prepared for Use with Fountain & Light Sets: All control panels come set up for fountain and light set. Light sets sold separately.
Support

Manual
Tech Specs
![]() 230V Control Panel
|
|
---|---|
Fountain Applications | PondSeries & LakeSeries Fountains |
Fountain Light Applications | Use with RGBW Color-Changing LED Fountain Lights |
Control Panel Type | Thermoset Fiberglass (NEMA 3R Rated) |
Installation | Hardwire |
Voltage/Amp Rating | 230V / 15A (1/2 HP Fountains) 230V / 20A (1 HP Fountains) 230V / 20A (2 HP Fountains) 230V / 30A (3 HP Fountains) 230V / 40A (5 HP Fountains) |
Auxiliary Option | None |
Protection | Overload Relay & GFCI |
Timers (Fountain/Lights) |
Digital / Programmable, 115V |
Enclosure Dimensions | 16"W x 17.75"H x 8.5"D |
Mounting Dimensions | 12"W x 18.25"H |
ETL Listed | Yes |
Warranty | Covered Under System Warranty |
Phase | 1 |
Hertz | 60 Hz |
How to Install
Airmax Control Panels are designed for outdoor use but should be mounted above any high water levels. Holes should be drilled into the bottom of the control panel for electrical access. We recommend using grommets to protect and seal the electrical access points and to help keep the control panel clean.
It is recommended that you have between 230 and 253 combined voltage on your incoming (L1 and L2) terminals. 208V power IS NOT ACCEPTABLE and will likely cause catastrophic failure to your power unit.
Reviews
Let Airmax design the right system for you! Airmax Assist™ is designed to take the guesswork out of aeration design and pond management. Simply fill out the online form with all pond information. Upon receipt, we will map, measure, and properly design an Airmax Aeration System. You will receive an aerial map with diffuser locations and complete system specifications.
Item Numbers and UPC
Item Number |
UPC Code |
Size |
---|---|---|
652107 | 813166026834 | 1/2 HP 230V |
652109 | 813166026858 | 1 HP 230V |
652113 | 813166026810 | 2 HP 230V |
652115 | 813166029934 | 3 HP 230V |
652525 | 810089840455 | 5 HP 230V |

Are you looking to add an Airmax Aeration System or Fountain? We have a network of certified pond professionals who provide installation services.